Error updating management module configuration data on the storage cell

Rated 3.94/5 based on 808 customer reviews

This process works on the ‘baby ASA’s,’ i.e 5506-X and 5508-X, and also on the larger models i.e 5512-X upwards (but NOT the 5585-X, that has a hw-module not a sw-module). INFO: No digital signature found 41848832 bytes copied in 5.20 secs (8369766 bytes/sec) Module sfr will be recovered. You then need to login to the SFR module and give it a basic config; Please review the final configuration: Hostname:Firepower-Module Management Interface Configuration IPv4 Configuration:static IP Address:192.168.1.253 Netmask:255.255.25.0 Gateway:192.168.1.254 IPv6 Configuration:Stateless autoconfiguration DNS Configuration: Domain:Search:DNS Server:10.3.0.2 NTP configuration: 1.71.49 .118 CAUTION: You have selected IPv6 stateless autoconfiguration, which assigns a global address based on network prefix and a device identifier. (y,n) [Y]: Now you can install the software package on the SFR module.

Before you start you need three things; Mod Card Type Model Serial No. This may erase all configuration and all data on that device and attempt to download/install a new image for it. Although this address is unlikely to change, if it does change, the system will stop functioning correctly. Note: the URL has TWO forward slashes in it not one, (Cisco update your documentation! WARNING You might want to set the SSH timeout to 45 minutes before you do this, or it will keep logging you out while you are waiting! ---- -------------------------------------------- ------------------ ----------- -X with SW, 8GE Data, 1GE Mgmt, AC ASA5506 JAD200XXXXX sfr Unknown N/A JAD200XXXXX Mod MAC Address Range Hw Version Fw Version Sw Version ---- --------------------------------- ------------ ------------ --------------- 1 00f2.8bfb.fbc8 to 00f2.8bfb.fbd1 1.1 1.1.8 9.5(2)2 sfr 00f2.8bfb.fbc7 to 00f2.8bfb.fbc7 N/A N/A Mod SSM Application Name Status SSM Application Version ---- ------------------------------ ---------------- -------------------------- Mod Status Data Plane Status Compatibility ---- ------------------ --------------------- ------------- 1 Up Sys Not Applicable sfr Recover Not Applicable WAIT AGES UNTIL... ---- -------------------------------------------- ------------------ ----------- -X with SW, 8GE Data, 1GE Mgmt, AC ASA5506 JAD200XXXXX sfr Fire POWER Services Software Module ASA5506 JAD200XXXXX Mod MAC Address Range Hw Version Fw Version Sw Version ---- --------------------------------- ------------ ------------ --------------- 1 00f2.8bfb.fbc8 to 00f2.8bfb.fbd1 1.1 1.1.8 9.5(2)2 sfr 00f2.8bfb.fbc7 to 00f2.8bfb.fbc7 N/A N/A 6.0.0-1005 Mod SSM Application Name Status SSM Application Version ---- ------------------------------ ---------------- -------------------------- sfr ASA Fire POWER Up 6.4.0-102 Mod Status Data Plane Status Compatibility ---- ------------------ --------------------- ------------- 1 Up Sys Not Applicable sfr Up Up Last login: Tue Mar 1 UTC 2016 on pts/0 Copyright 2004-2015, Cisco and/or its affiliates. Cisco is a registered trademark of Cisco Systems, Inc.

'configure manager add DONTRESOLVE [registration key ] [ NAT ID ]' Later, using the web interface on the Firepower Management Center, you must use the same registration key and, if necessary, the same NAT ID when you add this sensor to the Firepower Management Center. Sending 5, 100-byte ICMP Echos to 192.168.1.123, timeout is 2 seconds: !!!!!

Success rate is 100 percent (5/5), round-trip min/avg/max = 1/1/1 ms Petes-ASA# wr mem Building configuration...

When you sign in to comment, IBM will provide your email, first name and last name to DISQUS.

error updating management module configuration data on the storage cell-84

error updating management module configuration data on the storage cell-51

error updating management module configuration data on the storage cell-58

A newly installed Io T Edge runtime reports an error code until configured with a valid manifest.

A deployment manifest tells an Io T Edge device (or a group of devices) which modules to install and how to configure them. These modules are part of the Io T Edge runtime that manages the Io T Edge device and the modules running on it.

For more information about these modules, see Understand the Io T Edge runtime and its architecture.

See Updating Fire POWER Module (From ASDM)Note: This ASDM upgrade will fail if the module is being managed by the Fire POWER Management center (Fire SIGHT), you can update it from there, or remove the peer association, then update it.

Normally I only have to do this if something’s gone wrong, and I can’t contact the module, or I’ve go a lot of them to do, and I don’t have direct management access. ---- -------------------------------------------- ------------------ ----------- -X with SW, 8GE Data, 1GE Mgmt, AC ASA5506 JAD200XXXXX sfr Fire POWER Services Software Module ASA5506 JAD200XXXXX Mod MAC Address Range Hw Version Fw Version Sw Version ---- --------------------------------- ------------ ------------ --------------- 1 00f2.8bfb.fbc8 to 00f2.8bfb.fbd1 1.1 1.1.8 9.5(2)2 sfr 00f2.8bfb.fbc7 to 00f2.8bfb.fbc7 N/A N/A 5.4.1-211 Mod SSM Application Name Status SSM Application Version ---- ------------------------------ ---------------- -------------------------- sfr ASA Fire POWER Not Applicable 5.4.1-211 Mod Status Data Plane Status Compatibility ---- ------------------ --------------------- ------------- 1 Up Sys Not Applicable sfr Recover Not Applicable SAMPLE DEBUG OUTPUT Mod-sfr 657This would be a good time to go get a coffee, it doesn’t take that long, the documentation at Cisco says 5 minutes, I’d wait at least 10!

Leave a Reply